It is a three phase H.V switch equipment of 12KV. 50Hz for breaking or closing load current. no-load transformer cable charging current and closing short-circuit current. The load switch with earth switch can bear short-circuit current.
It is made up of FN12-12D load switch and SLAJ-12(XRNT-10) H.V current-limiting fuse box. It can break any current, load switch breaking working current and fuse box breaking short-circuit current. jointly breaking any current between short-circuit current. meantime. fuse box make the switch off of with the striker.
Application
It is used in the ring network city distribution and industrial equipment of 12KV and three-phase AC 50Hz to cortrol load and short-circuit. because the switch with fuse protecting transformer etc more reliably than circuit breaker. It is especialy suitable for ring network clouble radial distribution and package substation.
Standard
a. GB3804-90 <<3-63KV AC H.V load switch>>.
B. GBXXXX-XX <<AC H.V load switch with fuse box>>(the same IEC420-1990).
C. GB1995-89 <<AC H.V isolate switch and earth switch>>.
| Number | Name | Unit | FN12-12D/630-20 | FN12-12D.R/100-31.5 |
| 1 | Rated voltage | kV | 12 | |
| 2 | Rated frequency | Hz | 50 | |
| 3 | Reated current | A | 630 | 100 |
| 4 | Lighting impulse resisting voltage | kV | 75/85 | |
| 5 | 1min power frequency with stand voltage | kV | 42/48 | |
| 6 | Rated heat - stability current | kA | 204S | |
| 7 | Rated machine-stability current | kA | 50 | |
| 8 | Rated closing current (peak) | kA | 50 | 50 |
| 9 | Rated short-circuit breaking current | kA | 31.5 | |
| 10 | Rated transfer current | kA | 1.5 | |
| 11 | Max. breaking current | kA | 1.8 | |
| 12 | Breaking no-load transformer capacity | Kva | 1250 | |
| 13 | Rated cable charging current | A | 10 | |
| 14 | Rated power load current breaking times | >100 | ||
| 15 | Switch-off time of rated power load current switch on-and-off | S | >0.06 | |
| 16 | Earth switch heat-stability current | kA | 20 | 20 |
| 17 | Earth switch heat-stability curreak (peak) | kA | 50 | 50 |
| 18 | Motor operating power valtage | V | AC220.110 | |
FN12-12D.R/125-31.5 H.V.Load Break Switch With fuse
Other Products from this Supplier
See more
load break switch, high voltage load break switch, indoor load break switch products from this supplier.
Product Showcase[30]
Products
- Circuit breaker [73]
- Load break switch [51]
- high and low voltage switch cabinet [48]
- Cable branch box [28]
- Contactor and Relay [26]
- electric substation [7]
- terminal connector [4]
- Automatic transfer switch [14]
- Cable joint [20]
- connector and terminal [5]
- Cable tie [3]
- splicing fitting [3]
- Others [59]
Company Info
Daya Electric Group Co., Ltd.
[China (Mainland)]
[Verified Member]
City: Wenzhou
Province/State: Zhejiang
Country/Region : China (Mainland)
Business Type:Manufacturer, Trading Company
Online Postings: Products